SPECIFICATIONS
Select from list below to view detailed specifications for The Lilium.
- FOUNDATION
Reinforced concrete bored piles and/or reinforced concrete footings and/or raft foundation and/or driven piles.
- SUPERSTRUCTURE
Reinforced concrete and/or Pre-cast reinforced concrete and/or structural steel.
- WALLS
- External Walls: Reinforced concrete and/or light weight concrete panel and/or pre-cast reinforced concrete wall and/or curtain wall system.
- Internal Walls: Reinforced concrete wall and/or light weight concrete panel and/or pre-cast reinforced concrete wall and/or concrete blocks and/or drywall partition.
- ROOF
Reinforced concrete roof and/or metal roof with insulation and waterproofing system.
- CEILING
a) Apartment
- Kitchen, Bathroom, WC, Utility, Yard, Unit Corridor, Balcony, AC Ledge
- 1st Storey: Room clearance not lower than 2700 mm;
- Typical Storey: Room clearance not lower than 2400 mm;
- Penthouse: Room clearance not lower than 2700 mm.
- 1st Storey: Bulkhead ceiling not lower than 2700 mm;
- Typical Storey: Bulkhead ceiling not lower than 2400 mm;
- Penthouse: Bulkhead ceiling not lower than 2400 mm.
- 1st Storey: Room clearance not lower than 4650 mm;
- Typical Storey: Room clearance not lower than 2900 mm;
- Penthouse: Room clearance not lower than 6200 mm.
- 1st Storey: Bulkhead ceiling not lower than 2700 mm;
- Typical Storey: Bulkhead ceiling not lower than 2400 mm;
- Penthouse: Bulkhead ceiling not lower than 2400 mm.
- 1st Storey: Room clearance not lower than 4650 mm;
- Typical Storey: Room clearance not lower than 2900 mm;
- Penthouse: Room clearance not lower than 2900 mm.
- 1st Storey: Bulkhead ceiling not lower than 2700 mm;
- Typical Storey: Bulkhead ceiling not lower than 2400 mm;
- Penthouse: Bulkhead ceiling not lower than 2400 mm.
- 1st Storey: Room clearance not lower than 4650 mm;
- Typical Storey: Room clearance not lower than 2900 mm;
- Penthouse: Room clearance not lower than 2900 mm.
- 1st Storey: Bulkhead ceiling not lower than 2700 mm;
- Typical Storey: Bulkhead ceiling not lower than 2400 mm;
- Penthouse: Bulkhead ceiling not lower than 2400 mm.
- 1st Storey: Ceiling not lower than 2700 mm
- Typical Storey: Ceiling not lower than 2400 mm
- 1st Storey: Ceiling not lower than 4650 mm
- Typical Storey: Ceiling not lower than 2900 mm
- Ceiling not lower than 2400 mm
- Bulkhead ceiling not lower than 2200 mm
- 1st Storey: Ceiling not lower than 2700mm
- Typical Storey: Ceiling not lower than 2400mm
- 1st Storey: Ceiling not lower than 4650 mm
- Typical Storey: Ceiling not lower than 2900 mm
- Other parts of the apartment
Concrete slab and/or ceiling board and/or ceiling box-up and/or cement sand plaster and/or skim coat with paint finish to designated area (where applicable)
Foyer:
Living / Dining:
Bedroom:
Family / Study:
Kitchen:
Yard / Utility:
Bathrooms, Powder Rooms, WCs and Other Toilets:
Unit Corridors:
Balcony / A/C ledge:
Skim coat and/or cement sand plaster with paint finish and/or bulkhead to designated areas (where applicable)
b) Common Area
- Lift lobbies at basement, 1st storey and typical lobbies
- Ceiling not lower than 4300 mm
- Ceiling not lower than 2550 mm
- Generally
Moisture resistant fibrous plaster board or calcium silicate board with paint and/or cement sand plaster with paint finish
Level 1 Lift Lobby:
Typical Lift Lobby:
Skim coat and/or cement sand plaster with paint finish and/or bulkhead to designated areas
- FINISHES
a) Wall
- Unit
- Skim coat and/or cement sand plaster with paint finish
- Tiles and/or skim coat and/or cement sand plaster with paint finish
- Common Area
- Tiles and/or skim coat and/or cement sand plaster with paint finish
- Skim coat and/ or cement sand plaster with paint finish
Living, Dining, Bedroom, Utility, Yard, Study, HS:
Kitchen, Bathroom, WC:
Lift Lobbies:
Basement Carpark:
b) Floor
- Unit
- Tiles
- Engineered timber flooring
- Cement sand screed
- Common Area
- Tiles
- Cement sand screed
- Floor hardener and/or epoxy paint
Living, Dining, Kitchen, Bathrooms, Balcony, WC, Utility, Yard, HS:
Bedroom:
AC Ledge:
Lift Lobbies:
Storey Shelter:
Basement Carpark:
- WINDOWS
All windows of the apartment shall be aluminium framed window with clear and/or tinted and/or frosted and/or spandrel glass (where applicable) and/or laminated glass
- DOORS
-
Main Entrance
Approved fire-rated timber door complete with digital lockset -
Living / Dining / Balcony
Aluminium framed sliding and/or swing glass door and/or fixed glass panel with clear and/or tinted and/or frosted glass -
Bedroom, Bathroom
Hollow core timber door -
Kitchen
Timber framed sliding door with fixed glass panel and/or timber door and/or sliding glass door -
WC, Utility, Yard
PVC slide and swing door -
Storey Shelter
Approved blast-proof metal door -
Household Shelter
Approved blast-proof metal door
Good quality locksets and ironmongery to be provided to all doors.
- SANITARY FITTINGS
a) Master Bathroom
-
1 shower cubicle with 1 shower mixer set with rain shower
Brand: Grohe -
1 wash basin
Brand: Roca -
1 mixer
Brand: Grohe -
1 wall hung water closet
Brand: Laufen -
1 toilet paper holder
Brand: Grohe - 1 mirror
Brand: -
b) Common Bathroom
-
1 shower cubicle with 1 shower mixer set
Brand: Grohe -
1 wash basin
Brand: Roca -
1 mixer
Brand: Grohe -
1 wall hung water closet
Brand: Laufen -
1 toilet paper holder
Brand: Grohe - 1 mirror
Brand: -
c) WC (where applicable)
- 1 shower set
Brand: - - 1 bib tap
Brand: - - 1 basin tap
Brand: - -
1 pedestal water closet
Brand: Johnson Suisse -
1 toilet paper holder
Brand: Grohe
- ELECTRICAL INSTALLATION
- Electrical wiring within the Unit shall generally be concealed, except those above the suspended (false) ceiling, within DB and at the AC ledge, which shall be in exposed conduits, trays or trunking.
- Refer to Electrical Schedule for details.
- TV / CABLE SERVICES / FM / TELEPHONE POINTS
Refer to Electrical Schedule for details.
- LIGHTNING PROTECTION
Lightning Protection System shall be provided in accordance with current edition of Singapore Standard SS555: 2010.
- PAINTING
-
External Wall
Spray textured coating and/or emulsion paint and/or other approved exterior paint -
Internal Wall
Emulsion paint
- WATERPROOFING
Waterproofing shall be provided to floor slabs of Bathrooms, Kitchen, WCs, Yard, Balcony, Reinforced Concrete Flat Roof, Planter, Swimming Pool and other Pools, Swimming Pool Balancing Tank, Landscape Deck, Basement Carparks (where applicable)
- DRIVEWAY AND CAR PARK
-
Surface driveway/Drop Off and Ramp
Concrete/stone pavers and/or tile and/or tarmac and/or concrete floor and/or stone and/ or grass-cell pavers to external driveway at designated areas (where applicable) -
Basement Car Park
Reinforced concrete slab with floor hardener
- RECREATION FACILITIES
- Entrance Green Wall
- Picnic Lawn
- Function Room
- Gym
- 30m Lap Pool
- Pool Deck
- Lily Pond
- Kid’s Pool
- Moonlight Garden
- Outdoor Fitness Area
- Kid’s Playground
- BBQ & Dining Pavilion
- Wellness Lawn
- Scented Garden
- Garden Walk
- ADDITIONAL ITEMS
a) Kitchen Cabinets
- Kitchen cabinets with quartz countertop
-
Sink
Brand: Franke -
Mixer
Brand: Grohe
b) Kitchen Appliances
-
Telescopic hood
Brand: Electrolux -
Built-in Induction hob (Type B)
Brand: Electrolux -
Built-in Gas hob (Type C, D & PH)
Brand: Electrolux -
Built-in Microwave with Grill and convection (Type B)
Brand: Electrolux -
Built-in oven (Type C, D & PH)
Brand: Electrolux -
Refrigerator
Brand: Electrolux -
Washer cum Dryer
Brand: Electrolux
c) Wardrobe
- Quality wardrobe to all bedrooms
d) Bathroom Vanity
- Bathroom cabinets with quartz countertop
e) Hot Water Supply
- Hot water supply shall be provided to all bathrooms and kitchen
f) Security System
- Intercom System to Units
- Access Control System at designated common areas
- Automatic car barrier access system provided at the Main Entrance
- Closed circuit television system (CCTV) at designated common areas
g) Air-Conditioning
-
Wall mounted fan coil units (FCU) to Living/Dining, Bedrooms
Brand: Daikin